Interim guidance published over fire damper safety fears


Uk trade team is contacting for urgent motion to review potential ventilation troubles ahead of comprehensive revamp of fire and smoke damper direction set to be posted later on this 12 months

New market steering has been printed to deal with worries about a prospective fireplace basic safety flaw that could impact dampers in a massive variety of ventilation systems.

Trade system BESA reported that is has presented the new VH001 bulletin as a free of charge piece of interim assistance before its releases a comprehensive update on fireplace dampers and smoke dampers later this calendar year.

The conclusion to release the interim guidance is based on problems about the need to have for urgent perform to change a big amount of dampers that have been incorrectly installed, BESA explained.  The scale of these incorrect installations was uncovered through normal annual screening of devices.

Graeme Fox, technical head with BESA, explained that a significant concern highlighted in the document is the amount of installations are failing to comply with the unique guidance set out by method makers. He known as for function to deal with the installations as shortly as doable.

Mr Fox identified the use of self-drilling ‘tek’ screws as owning triggered possible protection troubles in methods. These screws are developed not to melt when temperature rise through a hearth. On the other hand, it is feared that this will affect the predicted efficiency of dampers.

Mr Fox additional, “This means spring-loaded dampers will not be released to contain the unfold of fire within the zone and assure the integrity of the fire stopping measure.”

“Dampers need to be secured by fusible fixings that allow the duct to split away otherwise the collapsing duct could pull the damper out of place and break the seal between the hearth zones.”

The tips within the VH001 bulletin have been approved by BESA’s technological committee and will be delivered free of charge by using the group’s website in purchase to aid discover probable problems with dampers.

Amongst the details incorporated in the direction is an updated selection of statutory requirements centered on the set up, screening and routine maintenance of fire and smoke dampers. This contains location out lawful obligations for individuals servicing or working on a system to ensure they meet the applicable nationwide specifications.

BESA stated the bulletin is developed to emphasize the importance of a penetration seal to the “fire stopping integrity” within an installation.

Mr Fox included that servicing teams have a vital position to aid uncover dampers in a technique to undertake screening and any repairs required.  There is also a will need for damper manufacturers to offer information for designers and developing engineers to use their merchandise.

Mr Fox extra that contractors were being getting urged to inform all consumers as soon as achievable about the will need for checks of their units.

He stated, “While this is clearly a pretty worrying predicament, we can consider some reassurance from the reality that this problem is being brought to our attention by the rising frequency of fire damper inspections and tests as consciousness grows of this very vital challenge.”

 